Thermal imaging report software that reads your camera files

    Thermal Reports runs in the browser. You upload the radiometric files from your camera, review each hot spot and issue the PDF report your client receives. It reads FLIR, Fluke and Hikmicro files, so a team with more than one camera brand can keep a single report standard.

    From radiometric file to PDF report

    1. 1

      Upload the thermal file

      Send the radiometric file exported by the camera. The temperatures come from the data stored in the file itself.

    2. 2

      Register the inspection point

      Link each image to the equipment and record the measurements and notes for that point.

    3. 3

      Review the classification

      The software rates the hot spot by ΔT against the reference you inform, and you review the result before it goes into the report.

    4. 4

      Generate the PDF

      The report comes out as a professional PDF with your branding, the images and the findings table.

    5. 5

      Share with the client

      Share the report by link or QR code, on the plans that include sharing (see the pricing page).

    Supported cameras and file formats

    The reader handles the following files, brand by brand:

    • FLIR: radiometric JPEG
    • Fluke: IS2 files
    • Hikmicro: radiometric JPEG

    A regular photo or a screenshot of the thermal image does not carry temperatures and is not read as thermal data. Export the original radiometric file from the camera.

    Multi-brand cameras, one thermography report standard

    Severity by ΔT, with the criterion printed in the report

    ΔT is the measured temperature minus the reference you inform: ambient air or a similar component under comparable load. From that difference the software assigns a severity level, and the report shows the reference and the criterion applied, so whoever reads it can see how each hot spot was rated.

    When the context needed for a rating is missing, such as the reference temperature, the point appears as not assessed. It is never shown as approved. The classification supports the technical assessment: it does not determine cause, time to failure or compliance on its own.

    ΔT in thermography: how to classify hot spot severity

    Routes, asset QR codes and history

    • Inspection routes with sequencing and status, so the team follows the same order every cycle (Professional plan and above).
    • A permanent QR code for each registered equipment: scanning it shows the inspection history of that asset, no login required (Professional plan and above).
    • Thermal baseline comparison across inspections to follow how a point changes over time (Team plan and above).

    From Thermal Inspection Route to Complete Technical Report

    Thermal Report Software Pricing

    Browser software vs desktop reporting tools

    A desktop reporting tool is installed on a computer, and the files, templates and reports stay there until someone moves them. Browser software has nothing to install: the team opens the same account from any computer with a connection, and inspections, reports and QR codes live in one place.

    The trade-off is that you need an internet connection to reach your account. The choice depends on how your team works, and the comparison article covers the criteria in more detail.

    Thermography Reports: How to Compare Reporting Methods

    Who is responsible for the report

    The software organizes the data and generates the document. Technical responsibility for the findings belongs to the qualified professional who signs the report.

    Frequently asked questions

    Which cameras and file formats does it read?

    FLIR radiometric JPEG, Fluke IS2 files and Hikmicro radiometric JPEG. A regular photo or a screenshot has no temperature data, so export the original radiometric file from the camera.

    Can I use my own logo on the report?

    Yes. On the Professional and Team plans you can customize the report header with your logo, name and company details. Client-branded report templates (white-label) are part of the Enterprise plan.

    How is severity classified, and what appears in the report?

    The software calculates ΔT as the measured temperature minus the reference you inform and assigns a severity level. The report shows the reference and the criterion applied. If the context needed is missing, the point is shown as not assessed, never as approved.

    Where is my data stored?

    According to the Privacy Policy, files such as thermal photos and PDF reports are stored on Backblaze B2 in the United States, with encryption at rest. Structured data such as registrations and inspections is stored in a PostgreSQL database via Supabase, on the company's own infrastructure. Backups are daily with 30-day retention, and on a deletion request your data is removed within 30 days.

    Who is responsible for the technical content of the report?

    The software organizes the data and generates the document. Technical responsibility for the findings belongs to the qualified professional who signs the report.

    Privacy Policy